Automatic Type Flame Tester
Model: SZ-6811A
This machine is to perform fire-protecting of insulator or sheathing. Test method is that fix the specimen to the position at which the tip of the test flame without any affects by breeze as well, and keep it there for 15seconds,then removed it for 15 seconds, then removed it for 15 seconds. To repeat the above actions for five times observes the burn-rate of the specimen. The SZ-6811A type is able to be set for test interval and times of the flame, and operated automatically.

Test Standard

  • UL 13-2007 功率限制电路电缆标准
  • UL 62-2010 软线和电缆
  • UL 94-2010 设备和器具部件材料的可燃性能试验
  • UL 444-2008 电信电缆的安全标准
  • UL 1581-2009 电线电缆和软线
  • UL 1655-2004 共用天线电视电缆

Specifications

Model

SZ-6811A

Vertical box Internal Dimensions

305×355×610mm

Level box Internal Dimensions

305×355×610mm

Vertical Type Burning Angle

Angle and sample for 20°

Horizontal Type Burning Angle

Angle and sample for 90°

Test Length

457mm (Vertical), 300mm (Level)

Test Fuel

Gas, Methane (User own equipment)

Mode Selection

Vertical or Horizontal: Manual/Automatic Selection

Power

1 AC220V 50HZ 5A