This machine is used for the heat deformation test of power cords. Put specimen into test chamber of this machine under a certain temperature for 30 minutes, then clamp specimen between two parallel plates, the upper plates being subject to a constant load under the same temperature for 30 minutes.
Afterwards, the differential thickness before/after heating is divided by the thickness before heating and multiplied by% for being unit, that is deformation rate.